Extreme Networks 10GB-C07-SFPP Compatible 10G SFP+ Passive Copper Twinax Cable, 7m (23ft)

The assembly listed here is the 7m (23ft) member of the 10GB-C07-SFPP product family for Extreme Networks equipment. It provides 10G DAC connectivity through SFP+ to SFP+. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: 10GB-C07-SFPPHT Part Number: 10GB-C07-SFPP
Product Highlights
- Compatible alternative to Extreme Networks 10GB-C07-SFPP
- 10G connectivity at 10Gbps
- Interface configuration: SFP+ to SFP+
- Fixed length and part number: 7m (23ft), 10GB-C07-SFPP
- Cable construction: Passive Twinax
- Conductor specification: 24AWG
- Maximum power consumption: ≤0.1W
- Minimum bend radius: 30mm
Specifications
| HT Part Number | 10GB-C07-SFPP |
|---|---|
| Extreme Compatible | SFP-H10GB-CU7M |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Media | Copper |
| Power Supply | 3.3V |
| Minimum Bend Radius | 30mm |
| Wire AWG | 24AWG |
| Cable Length | 7m (22.97ft) |
| Jacket Material | PVC (OFNR) |
| Cable Type | Passive Twinax |
| Temperature | 0 to 70°C (32 to 158°F) |
| Power Consumption | ≤0.1W |
| Application | 10G Ethernet |
| Protocols | 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel |
Power and Thermal Planning
The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 24AWG; the minimum bend radius is 30mm; the stated power consumption is ≤0.1W; the jacket material is PVC (OFNR).
Cable Construction and Routing
This assembly uses 24AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 10G Ethernet. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
Measure twice before deploying this 7m (23ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the complete copper assembly and both connector housings, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. The next shorter verified assembly is 10GB-C05-SFPP at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.
Position Within the Length Range
10GB-C07-SFPP is the longest of 9 verified length options in this family. Compared with 10GB-C05-SFPP at 5m (16ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Extreme Networks Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original Extreme Networks cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Extreme Networks 10GB-C07-SFPP.
Does this order code cover multiple lengths?
No. 10GB-C07-SFPP refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 7m (23ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.