MTP-12 to MTP-12 APC Jumper, 8 Fibers, OS2, Type B

Factory assembled MTP® Elite Female jumper cable with 8 Fibers, OS2 9/125μm and Plenum (OFNP) jacket. Every unit is measured for insertion loss and return loss before packing, so the link budget you calculate on paper is the one you get in the rack.
Available lengths are 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft) and 10m (33ft). We can also produce any intermediate or longer length to order, with your choice of labeling and packaging.
Product Highlights
- MTP® Elite Female (Non-Pinned) to MTP® Elite Female (Non-Pinned), 8 Fibers
- OS2 9/125μm, G.657.A1
- Insertion loss ≤0.35dB (0.15dB Typ.), return loss ≥60dB
- Type B polarity
- 3.0mm Plenum (OFNP) round cable
- Minimum bend radius 10mm
- Stock lengths from 1m (3ft) to 10m (33ft), custom lengths on request
Specifications
| Part Number | 12FMTPSMF |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MTP® Elite Female (Non-Pinned) |
| Connector B | US Conec MTP® Elite Female (Non-Pinned) |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Polish Type | APC to APC |
| Polarity | Type B |
| Cable Jacket | Plenum (OFNP) |
| Fiber Count | 8 Fibers |
| Glass Fiber | G.657.A1 |
| Cable Outside Diameter (OD) | 3.0mm |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Connector Durability | 500 times |
| Tensile Strength | 80/240N (Long/Short Term) |
| Insertion Loss | ≤0.35dB (0.15dB Typ.) |
| Return Loss | ≥60dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
Applications
This jumper is intended for high density data center patching. The 8-fiber version matches 400G and 800G parallel interfaces that run on 4 or 8 lanes, such as QSFP112, OSFP and twin-port OSFP connections. It works equally well in new structured cabling builds and in day-to-day moves, adds and changes where fast, error-free reconnection matters.
Polarity and Gender Options
The same jumper can be produced with different polarity and gender combinations. Male connectors carry guide pins for direct module connection, while female versions are used at panels. Polarity A, B and C are all standard for us, and our engineers can check your link diagram if you are unsure which one to order.
Ordering Information
To order, quote 12FMTPSMF together with the length and quantity you need. Private labeling, custom packaging and project specific documentation are all handled in-house.