Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

Brocade 40G-QSFP-4SFP-C-0101 Compatible 40G QSFP+ to 4 x 10G SFP+ Passive Copper Breakout Cable, 1m (3ft)

Brocade 40G-QSFP-4SFP-C-0101 Compatible 40G QSFP+ to 4 x 10G SFP+ Passive Copper Breakout Cable, 1m (3ft)

For project documentation, Brocade 40G-QSFP-4SFP-C-0101 and this cable’s physical length should be recorded together. The product described here is a 1m (3ft) DAC assembly for 40G links, using QSFP+ to 4 SFP+. Its OEM cross-reference, HT part number, specification table and packing options support traceable ordering and installation records.

OEM Part Number: 40G-QSFP-4SFP-C-0101HT Part Number: 40G-QSFP-4SFP-C-0101

Product Highlights

  • Compatible alternative to Brocade 40G-QSFP-4SFP-C-0101
  • 40G connectivity at 40Gbps
  • Interface configuration: QSFP+ to 4 SFP+
  • Fixed length and part number: 1m (3ft), 40G-QSFP-4SFP-C-0101
  • Conductor specification: 30AWG
  • Minimum bend radius: 21mm

Specifications

HT Part Number40G-QSFP-4SFP-C-0101
Brocade Compatible40G-QSFP-4SFP-C-0101
ManufacturerHT
Connector TypeQSFP+ to 4 SFP+
Max Data Rate40Gbps
Minimum Bend Radius21mm
Wire AWG30AWG
Cable Length1m (3.28ft)
Jacket MaterialPVC (OFNR)
Temperature0 to 70°C (32 to 158°F)
ProtocolsSFF-8436, SFF-8431 and QSFP+ MSA

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 21mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431 and QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP+ to 4 SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), 40G-QSFP-4SFP-C-0101 is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

40G-QSFP-4SFP-C-0101 occupies the middle of this family between 40G-QSFP-4SFP-C-0105 at 0.5m (2ft) and 40G-QSFP-4SFP-C-0201 at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 21mm; the jacket material is PVC (OFNR).

Brocade Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original Brocade cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 40G-QSFP-4SFP-C-0101.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles