800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Copper Breakout Cable, 5m (16ft)

The assembly listed here is the 5m (16ft) member of the 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FT product family for Generic equipment. It provides 800G ACC connectivity through 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top). Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FTHT Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FT
Product Highlights
- HT-manufactured ACC assembly in 5m (16ft)
- 800G connectivity at 800Gbps
- Interface configuration: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)
- Fixed length and part number: 5m (16ft), 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FT
- Cable construction: Active Breakout DAC (ACC)
- Conductor specification: 26AWG
- Maximum power consumption: 1.5W (800G End)/0.6W (400G Per End)
- Minimum bend radius: 40mm
Specifications
| HT Part Number | 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active Breakout DAC (ACC) |
| Cable Length | 5m (16ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 40mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | 1.5W (800G End)/0.6W (400G Per End) |
| Modulation Format | 8x 100G-PAM4 to Dual 4x 100G-PMA4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/400G Ethernet |
| Protocols | OSFP MSA, CMIS 5.0, IEEE 802.3 ck |
Signal and Lane Configuration
The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PMA4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 40mm; the stated power consumption is 1.5W (800G End)/0.6W (400G Per End); the jacket material is PET.
Power and Thermal Planning
The rated power consumption is 1.5W (800G End)/0.6W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 40mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA, CMIS 5.0, IEEE 802.3 ck. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Length Selection and Installation Planning
The 5m (16ft) length gives 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
Position Within the Length Range
800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FT is the longest of 5 verified length options in this family. Compared with 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-4M13FT at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-5M16FT.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Neutral packaging and customer-specific packing documentation are available on request.