Dell AOC-Q28DD-2Q28-100G-5M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 5m (16ft)

The assembly listed here is the 5m (16ft) member of the AOC-Q28DD-2Q28-100G-5M product family for Dell equipment. It provides 200G AOC connectivity through QSFP-DD to 2x 100G QSFP28. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: AOC-Q28DD-2Q28-100G-5MHT Part Number: AOC-Q28DD-2Q28-100G-5M
Product Highlights
- Compatible alternative to Dell AOC-Q28DD-2Q28-100G-5M
- 200G connectivity at 200Gbps
- Interface configuration: QSFP-DD to 2x 100G QSFP28
- Fixed length and part number: 5m (16ft), AOC-Q28DD-2Q28-100G-5M
- Cable construction: OM3
- Maximum power consumption: 4W (QSFP-DD End) 2.5W (QSFP28 Per End)
- Minimum bend radius: 30mm
- Operating temperature: 0 to 70°C (32 to 158°F)
Specifications
| HT Part Number | AOC-Q28DD-2Q28-100G-5M |
|---|---|
| Dell Compatible | AOC-Q28DD-2Q28-100G-5M |
| Manufacturer | HT |
| Form Factor | QSFP-DD to 2x 100G QSFP28 |
| Max. Data Rate | 200Gbps |
| Cable Length | 5m (16ft) |
| Cable Type | OM3 |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 4W (QSFP-DD End) 2.5W (QSFP28 Per End) |
| Jacket Material | OFNP |
| CDR (Clock and Data Recovery) | Not Supported |
| Modulation Format | NRZ |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636 |
Signal and Lane Configuration
The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP-DD to 2x 100G QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
The 5m (16ft) length gives AOC-Q28DD-2Q28-100G-5M more freedom for adjacent-rack and row-end deployments. The integrated optical assembly should be supported along its route without tight bends or connector pull loads; the AOC specification and host support must still match the intended link.
Position Within the Length Range
AOC-Q28DD-2Q28-100G-5M occupies the middle of this family between AOC-Q28DD-2Q28-100G-3M at 3m (10ft) and AOC-Q28DD-2Q28-100G-7M at 7m (23ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End); the jacket material is OFNP.
Dell Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Frequently Asked Questions
Is this an original Dell cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Dell AOC-Q28DD-2Q28-100G-5M.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. AOC-Q28DD-2Q28-100G-5M refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Neutral packaging and customer-specific packing documentation are available on request.
