Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

Ericsson CWDM-SFP10G-1270-10-I Compatible 10G SFP+ Transceiver Module

Ericsson CWDM-SFP10G-1270-10-I Compatible 10G SFP+ Transceiver Module

The CWDM-SFP10G-1270-10-I compatible module serves equipment requiring a 10G SFP+ interface with 1270nm optics and a 10km rating. Connection is through Duplex LC. Product data, application guidance and factory verification are presented together to support project teams keep OEM references, delivery records and port schedules aligned.

OEM Part Number: CWDM-SFP10G-1270-10-IHT Part Number: CWDM-SFP10G-1270-10-I

Product Highlights

  • Compatible alternative to Ericsson CWDM-SFP10G-1270-10-I
  • 10G connectivity at 10.31Gbps
  • Optical wavelength: 1270nm
  • Specified reach: 10km
  • Duplex LC / SMF interface
  • Digital diagnostic monitoring: Supported
  • Operating temperature: -40 to 85°C (-40 to 185°F)

Specifications

HT Part NumberCWDM-SFP10G-1270-10-I
ManufacturerHT
Form FactorSFP+
Max Data Rate10.31Gbps
Wavelength1270nm
Max Cable Distance10km
ConnectorDuplex LC
MediaSMF
Transmitter TypeDFB
Receiver TypePIN
TX Power-1~5dBm
Receiver Sensitivity<-14.4dBm
Power Budget>15dB
Receiver Overload>0dB
Typical Power Consumption<1.2W
Extinction Ratio>3.5dB
DDM/DOMSupported
Industrial Temperature Range-40 to 85°C (-40 to 185°F)
ProtocolsSFP+ MSA, SFF-8472

Project Documentation and Traceability

Large deployments are easier to audit when the order code, optical standard and endpoint record agree. Keep the OEM reference in the compatibility document and the HT part number on the packing list. Labels and carton groups can be arranged by rack or port plan so installers need not identify modules by appearance. For this model, the principal parameters are data rate 10.31Gbps, wavelength 1270nm, rated reach 10km.

Ericsson Compatibility and Factory Testing

Factory verification starts with the expected CWDM-SFP10G-1270-10-I identity and finishes with an operating host link. EEPROM data, diagnostic visibility and the stated optical parameters are assessed together. Equipment model, hardware revision and software release can be reviewed before dispatch where platform behavior is uncertain.

Applications and Optical Link Design

Use this module for equipment interconnection over the specified single-mode fiber plant, including enterprise backbone, campus, metro or data-center interconnect links according to its rated distance. Confirm that both ends use the same optical standard and wavelength plan, and allow for connector, splice and patch-panel loss within the stated power budget.

The industrial temperature rating makes this version appropriate for controlled outdoor cabinets, transport nodes and other installations exposed to wider ambient temperature variation. Adequate airflow, protected cable routing and host-platform temperature limits still apply.

For this 1270nm interface, verify channel spacing and filter compatibility. Passive filters add loss even without active equipment, so assess 10km using the complete channel rather than fiber distance alone.

Optical Acceptance, Diagnostics and Handling

For this model, the specified transmit-power range is -1~5dBm; receiver sensitivity is <-14.4dBm; the stated optical power budget is >15dB. During commissioning, record the host diagnostic readings after the link has stabilized and compare them with those limits. DOM values are useful operational indicators, but they do not replace calibrated optical measurements when a link is marginal. Investigate unexpected loss through connector inspection, cleaning and a channel measurement before replacing the module. Diagnostic monitoring is listed as Supported. Before every insertion, keep dust caps in place until the patch lead is ready, avoid touching the optical end face and use an appropriate inspection and cleaning procedure. Do not look into an active optical interface.

Frequently Asked Questions

Is this an original Ericsson transceiver?

No. It is an HT-manufactured compatible alternative for equipment that specifies CWDM-SFP10G-1270-10-I, not an original Ericsson-branded module.

Which fiber and connector are required?

Use Duplex LC with SMF. The specified maximum reach is 10km, subject to fiber quality and total link loss.

Can it be mixed with another wavelength or reach version?

Only when the two ends share the same optical standard, wavelength plan and supported data rate. Check the exact part numbers and link budget rather than relying only on the module form factor.

Ordering Information

When ordering, specify CWDM-SFP10G-1270-10-I, CWDM-SFP10G-1270-10-I, quantity and intended host platform. Project labels can repeat these details for receiving and asset records. Neutral labels, customer packaging and project-specific compatibility review are available on request.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, with production lead times confirmed for larger quantities. International courier, air freight and sea freight are available; customer courier accounts and nominated forwarders are accepted.

Quality Assurance and Packaging

Quality control covers the optical or electrical interface, host identification and operating link. The verified unit is then individually protected and cartoned. Customer references, rack groups and project packing lists can be added for volume orders.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles