Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

Dell (DE) DAC-Q28-4SFP28-25G-1M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1m (3ft)

Dell (DE) DAC-Q28-4SFP28-25G-1M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1m (3ft)

The assembly listed here is the 1m (3ft) member of the DAC-Q28-4SFP28-25G-1M product family for Dell (DE) equipment. It provides 100G DAC connectivity through QSFP28 to SFP28. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.

OEM Part Number: DAC-Q28-4SFP28-25G-1MHT Part Number: DAC-Q28-4SFP28-25G-1M

Product Highlights

  • Compatible alternative to Dell (DE) DAC-Q28-4SFP28-25G-1M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to SFP28
  • Fixed length and part number: 1m (3ft), DAC-Q28-4SFP28-25G-1M
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.125W
  • Minimum bend radius: 60mm

Specifications

HT Part NumberDAC-Q28-4SFP28-25G-1M
Dell (DE) CompatibleDAC-Q28-4SFP28-25G-1M
ManufacturerHT
Form FactorQSFP28 to SFP28
Max Data Rate100Gbps
Cable TypePassive Twinax
Cable Length1m (3ft)
Wire AWG30AWG
Minimum Bend Radius60mm
Power Consumption≤0.125W
Power Supply3.3V
MTBF=50 Million Hours
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
MediaCopper
Application100G to 4x 25G Ethernet, Data Centers
ProtocolsIEEE 802.3, QSFP28 MSA, SFF-8665

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), DAC-Q28-4SFP28-25G-1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

DAC-Q28-4SFP28-25G-1M occupies the middle of this family between DAC-Q28-4SFP28-25G-0.5M at 0.5m (2ft) and DAC-Q28-4SFP28-25G-1.5M at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 60mm; the stated power consumption is ≤0.125W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Dell (DE) Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original Dell (DE) cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Dell (DE) DAC-Q28-4SFP28-25G-1M.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. DAC-Q28-4SFP28-25G-1M refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles