Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

Juniper Networks JNP-100G-AOCBO-50M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 50m (164ft)

Juniper Networks JNP-100G-AOCBO-50M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 50m (164ft)

This JNP-100G-AOCBO-50M compatible cable gives project teams a defined 100G connection in 50m (164ft), with QSFP28 to 4x SFP28 and Juniper Networks host compatibility. Rather than treating all lengths as interchangeable, the page keeps this order code separate and links the other verified lengths for accurate schedules, labels and delivery checks.

OEM Part Number: JNP-100G-AOCBO-50MHT Part Number: JNP-100G-AOCBO-50M

Product Highlights

  • Compatible alternative to Juniper Networks JNP-100G-AOCBO-50M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 4x SFP28
  • Fixed length and part number: 50m (164ft), JNP-100G-AOCBO-50M
  • Cable construction: Breakout AOC
  • Maximum power consumption: 2.2W (QSFP28 End)0.8W (SFP28 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberJNP-100G-AOCBO-50M
Juniper Networks CompatibleJNP-100G-AOCBO-50M
ManufacturerHT
Form FactorQSFP28 to 4x SFP28
Max. Data Rate100Gbps
Cable Length50m (164ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption2.2W (QSFP28 End)0.8W (SFP28 Per End)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP28 MSA, SFP28 MSA

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

This 50m (164ft) assembly is intended for routes that shorter members of the same family cannot serve comfortably. Before ordering, document the actual pathway and the space available for service access. During installation, secure the integrated optical cable and both optical engines without compressing it into an undersized bundle or leaving its weight suspended from the ports. The next shorter verified assembly is JNP-100G-AOCBO-30M at 30m (98ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

JNP-100G-AOCBO-50M is the longest of 11 verified length options in this family. Compared with JNP-100G-AOCBO-30M at 30m (98ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End); the jacket material is OFNP.

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Juniper Networks Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks JNP-100G-AOCBO-50M.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. JNP-100G-AOCBO-50M refers here to 50m (164ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to JNP-100G-AOCBO-50M.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles