Juniper Networks JNP-10G-AOC-30M Compatible 10G SFP+ Active Optical Cable, 30m (98ft)

This JNP-10G-AOC-30M compatible cable gives project teams a defined 10G connection in 30m (98ft), with SFP+ to SFP+ and Juniper Networks host compatibility. Rather than treating all lengths as interchangeable, the page keeps this order code separate and links the other verified lengths for accurate schedules, labels and delivery checks.
OEM Part Number: JNP-10G-AOC-30MHT Part Number: JNP-10G-AOC-30M
Product Highlights
- Compatible alternative to Juniper Networks JNP-10G-AOC-30M
- 10G connectivity at 10Gbps
- Interface configuration: SFP+ to SFP+
- Fixed length and part number: 30m (98ft), JNP-10G-AOC-30M
- Cable construction: OM3
- Maximum power consumption: <0.8W
- Minimum bend radius: 30mm
Specifications
| HT Part Number | JNP-10G-AOC-30M |
|---|---|
| Juniper Networks Compatible | JNP-10G-AOC-30M |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Cable Type | OM3 |
| Cable Length | 30m (98.43ft) |
| Minimum Bend Radius | 30mm |
| Power Consumption | <0.8W |
| Jacket Material | OFNP |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet |
Juniper Deployment Reference
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the minimum bend radius is 30mm; the stated power consumption is <0.8W; the jacket material is OFNP.
Power and Thermal Planning
The rated power consumption is <0.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet. Confirm that the host firmware and port configuration support the same operating mode.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
Extended reach changes the installation checks for JNP-10G-AOC-30M. Confirm that 30m (98ft) follows the intended route without tension, then verify that intermediate supports do not squeeze the jacket or hide the connectors behind adjacent cables. Both hosts must still match the stated interface and lane configuration. The next shorter verified assembly is JNP-10G-AOC-25M at 25m (82ft), which is the better comparison when the managed route leaves substantial unused cable.
Position Within the Length Range
JNP-10G-AOC-30M is the longest of 10 verified length options in this family. Compared with JNP-10G-AOC-25M at 25m (82ft), it provides 5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Juniper Networks Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original Juniper Networks cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks JNP-10G-AOC-30M.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to JNP-10G-AOC-30M.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.