Juniper Networks JNP-25G-AOC-15M Compatible 25G SFP28 Active Optical Cable, 15m (49ft)

The assembly listed here is the 15m (49ft) member of the JNP-25G-AOC-15M product family for Juniper Networks equipment. It provides 25G AOC connectivity through SFP28 to SFP28. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: JNP-25G-AOC-15MHT Part Number: JNP-25G-AOC-15M
Product Highlights
- Compatible alternative to Juniper Networks JNP-25G-AOC-15M
- 25G connectivity at 25Gbps
- Interface configuration: SFP28 to SFP28
- Fixed length and part number: 15m (49ft), JNP-25G-AOC-15M
- Minimum bend radius: 30mm
Specifications
| HT Part Number | JNP-25G-AOC-15M |
|---|---|
| Juniper Networks Compatible | JNP-25G-AOC-15M |
| Manufacturer | HT |
| Connector Type | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 15m (49.21ft) |
| Jacket Material | OFNP |
| Temperature | 0 to 70°C (32 to 158°F) |
Juniper Deployment Reference
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
Position Within the Length Range
JNP-25G-AOC-15M occupies the middle of this family between JNP-25G-AOC-10M at 10m (33ft) and JNP-25G-AOC-20M at 20m (66ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the minimum bend radius is 30mm; the jacket material is OFNP.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
The 15m (49ft) reach of JNP-25G-AOC-15M is useful only when the managed pathway requires it; straight-line distance between ports is not a sufficient measurement. Check the route around rack rails, cable managers and maintenance clearances, then protect the integrated optical cable and both optical engines from tight bends and unsupported spans. Within this family, JNP-25G-AOC-10M is shorter at 10m (33ft), while JNP-25G-AOC-20M is the next longer choice at 20m (66ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Juniper Networks Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original Juniper Networks cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks JNP-25G-AOC-15M.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Keep JNP-25G-AOC-15M associated with 15m (49ft) throughout the order and receiving record.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Neutral packaging and customer-specific packing documentation are available on request.
