LC UPC to LC UPC Duplex Flat Clip Uniboot OM4, 2.0mm, ofnr Fiber Patch Cable

LC UPC to LC UPC Duplex Flat Clip Uniboot OM4, 2.0mm, ofnr Fiber Patch Cable

For Pakistani procurement and engineering teams, the specification provides a practical basis for checking compatibility before production is requested. This OM4 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OM4 glass and optically tested as an entire unit. The uniboot build places the two fibers of the duplex connection inside a single round 2.0mm cord with one combined connector housing, halving the installed cable count in dense panels and simplifying polarity management.

Product Highlights

  • Uniboot Allows One Cable to Carry Two Fibers to Reduce Cable Congestion in High-Density Patch Fields
  • Bend Insensitive Fiber with 7.5mm Min. Bend Radius
  • Flat Clip Design Provides Additional Space Between Connectors and Improves Airflow
  • Reverse Polarity without Exposing the Fibers or Needing Any Tools
  • Termination Is Tested to Ensure Network Performance

Specifications

Fiber Count2 Fibers
Fiber GradeBend Insensitive Fiber
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Flame RatingRiser (OFNR)
Cable Outside Diameter (OD)2.0mm
PolarityA (Tx) to B (Rx)
Tensile Strength60/100N (Long/Short Term)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Insertion Loss≤0.2dB
Return Loss≥30dB
Attenuation at 850nm≤3.5 dB/km
Attenuation at 1300nm≤1.5 dB/km
Operating Temperature-10 to 70°C (14 to 158℉)
Storage Temperature-20 to 70℃ (-4 to 158℉)

Polarity and pairing in duplex links

A duplex jumper is two fibers with a defined A-to-B crossover. Getting polarity right at the cord level keeps the link consistent end to end, which is why these assemblies are built and tested as a pair rather than as two individual strands.

Multimode reach for the data hall

This OM4 unit serves the short-reach fabric of the data center: 10G and 25G server uplinks, 40G and 100G SR4 spine links and the inter-row runs between them. On OM4 glass, 10G Ethernet holds to 400 meters and 100G SR4 to 100 meters, which covers the overwhelming majority of in-hall routes with margin to spare.

Polarity without re-terminating

Uniboot connectors expose the polarity through the housing rather than the termination: the latches or clips let the installer swap the fiber positions without opening the cord. A polarity mistake discovered at turn-up becomes a two-minute correction instead of a replacement order. For Pakistani projects, include this point in the technical enquiry and final installation checklist.

Length Options

Catalogue lengths cover the common patching routes: 0.5m (1.6ft), 1m (3ft), 1.5m (5ft), 2m (7ft), 3m (10ft), 4m (13ft), 5m (16ft), with custom-built length offered beyond the list. Specifying the measured path length keeps the slack out of the manager and the strain off the optical interfaces.

Quality Control and Testing

Every manufactured assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on every cable, and end-face geometry is inspected for consistent physical contact. The installed cable ships with dust caps on the two connectors and the test result offered on specify.

Ordering and Factory Support

Refer to this setup by connector pair, fiber mode and length when specifying a quotation. For configurations outside the listed options, mixed connector families, jackets, identification or project packing, send the specification with the request and the factory will make certain of the build before factory assembly. For Pakistan, a clear port or maintenance schedule helps us confirm the correct factory-built configuration before supply.