Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

LC UPC to LC UPC Simplex OM4, 1.2mm, ofnr Fiber Patch Cable

LC UPC to LC UPC Simplex OM4, 1.2mm, ofnr Fiber Patch Cable

For Pakistani procurement and engineering teams, the specification provides a practical basis for checking compatibility before production is requested. This OM4 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OM4 glass and optically tested as an entire unit. The single-fiber build suits bidirectional optics, monitoring taps and any connection that carries traffic over one strand.

Product Highlights

  • Bend Insensitive Fiber with 7.5mm Min. Bend Radius
  • Precision Zirconia Ferrule Connectors Ensure Low Loss
  • Thinner Cable Diameter Delivers Enhanced Flexibility for Tight Spaces and Complex Routing
  • Flame-Retardant Riser (OFNR) for Vertical and Floor-to-Floor Installations
  • Color-Coded Cable Jacket for Easy Identification

Specifications

Connector ALC UPC Simplex
Connector BLC UPC Simplex
Fiber Count1 Fiber
Fiber GradeBend Insensitive Fiber
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Flame RatingRiser (OFNR)
Cable Outside Diameter (OD)1.2mm
Cable TypeTight-Buffered
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Connector Durability1000 times
Tensile Strength20/40N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥30dB
Attenuation at 850nm≤3.5dB/km
Attenuation at 1300nm≤1.5dB/km
Operating Temperature-10 to 70°C (14 to 158°F)
Storage Temperature-20 to 70°C (-4 to 158°F)

Polarity and pairing in duplex links

A duplex jumper is two fibers with a defined A-to-B crossover. Getting polarity right at the cord level keeps the link consistent end to end, which is why these assemblies are built and tested as a pair rather than as two individual strands.

Multimode reach for the data hall

This OM4 unit serves the short-reach fabric of the data center: 10G and 25G server uplinks, 40G and 100G SR4 spine links and the inter-row runs between them. On OM4 glass, 10G Ethernet holds to 400 meters and 100G SR4 to 100 meters, which covers the overwhelming majority of in-hall routes with margin to spare.

Length Options

Catalogue lengths cover the common patching routes: 2m (7ft), 3m (10ft), 5m (16ft), with custom-built length offered beyond the list. Specifying the measured path length keeps the slack out of the manager and the strain off the optical interfaces.

Quality Control and Testing

Every manufactured assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on every cable, and end-face geometry is inspected for consistent physical contact. The installed cable ships with dust caps on the two connectors and the test result offered on specify.

Ordering and Factory Support

Refer to this setup by connector pair, fiber mode and length when specifying a quotation. For configurations outside the listed options, mixed connector families, jackets, identification or project packing, send the specification with the request and the factory will make certain of the build before factory assembly. For Pakistan, a clear port or maintenance schedule helps us confirm the correct factory-built configuration before supply.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles