NVIDIA/Mellanox MCA7J75-N005 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G QSFP112 2 x 100G PAM4 InfiniBand NDR Active Copper Breakout Cable, 5m (16ft)

This MCA7J75-N005 compatible cable gives project teams a defined 800G connection in 5m (16ft), with OSFP (IHS/Finned Top) to 4x QSFP112 and NVIDIA/Mellanox host compatibility. Rather than treating all lengths as interchangeable, the page keeps this order code separate and links the other verified lengths for accurate schedules, labels and delivery checks.
OEM Part Number: MCA7J75-N005HT Part Number: MCA7J75-N005
Product Highlights
- Compatible alternative to NVIDIA/Mellanox MCA7J75-N005
- 800G connectivity at 800Gbps
- Interface configuration: OSFP (IHS/Finned Top) to 4x QSFP112
- Fixed length and part number: 5m (16ft), MCA7J75-N005
- Cable construction: Active Breakout DAC (ACC)
- Conductor specification: 26AWG
- Maximum power consumption: 1.7W (OSFP End)0.3W (QSFP112 Per End)
- Minimum bend radius: 32.5mm
Specifications
| HT Part Number | MCA7J75-N005 |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCA7J75-N005 |
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 4x QSFP112 |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active Breakout DAC (ACC) |
| Minimum Bend Radius | 32.5mm |
| Wire AWG | 26AWG |
| Cable Length | 5m (16ft) |
| Jacket Material | PET |
| Max. Power Consumption | 1.7W (OSFP End)0.3W (QSFP112 Per End) |
| Modulation Format | OSFP-8x 100G-PAM4QSFP112-2x 100G-PAM4 |
| DDM/DOM | Not Supported |
| Commercial TemperatureRange | 0 to 70°C (32 to 158°F) |
| Protocols | OSFP MSA Rev5.0, QSFP112 MSA, IEEE 802.3ck, CMIS 5.0 |
Signal and Lane Configuration
The listed modulation format is OSFP-8x 100G-PAM4QSFP112-2x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA Rev5.0, QSFP112 MSA, IEEE 802.3ck, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The OSFP (IHS/Finned Top) to 4x QSFP112 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Length Selection and Installation Planning
The 5m (16ft) length gives MCA7J75-N005 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
Position Within the Length Range
MCA7J75-N005 is the longest of 5 verified length options in this family. Compared with MCA7J75-N004 at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 32.5mm; the stated power consumption is 1.7W (OSFP End)0.3W (QSFP112 Per End); the jacket material is PET.
Power and Thermal Planning
The rated power consumption is 1.7W (OSFP End)0.3W (QSFP112 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 32.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
NVIDIA/Mellanox Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original NVIDIA/Mellanox cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA7J75-N005.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. MCA7J75-N005 refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.