NVIDIA/Mellanox MCP7H50-H01AR30 Compatible 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP56 2 x 50G PAM4 InfiniBand HDR Passive Copper Breakout Cable, 1.5m (5ft)

For project documentation, NVIDIA/Mellanox MCP7H50-H01AR30 and this cable’s physical length should be recorded together. The product described here is a 1.5m (5ft) DAC assembly for 200G links, using QSFP56 to 2 QSFP56. Its OEM cross-reference, HT part number, specification table and packing options support traceable ordering and installation records.
OEM Part Number: MCP7H50-H01AR30HT Part Number: MCP7H50-H01AR30
Product Highlights
- Compatible alternative to NVIDIA/Mellanox MCP7H50-H01AR30
- 200G connectivity at 200Gbps
- Interface configuration: QSFP56 to 2 QSFP56
- Fixed length and part number: 1.5m (5ft), MCP7H50-H01AR30
- Cable construction: Passive Twinax
- Conductor specification: 26AWG
- Maximum power consumption: 0.1W (200G End) 0.1W (100G Per End)
- Minimum bend radius: 26mm
Specifications
| HT Part Number | MCP7H50-H01AR30 |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCP7H50-H01AR30 |
| Manufacturer | HT |
| Form Factor | QSFP56 to 2 QSFP56 |
| Max. Data Rate | 200Gbps |
| Cable Length | 1.5m (5ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 26mm |
| Max. Power Consumption | 0.1W (200G End) 0.1W (100G Per End) |
| Cable Type | Passive Twinax |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, SFF-8665, SFF-8665 |
Power and Thermal Planning
The rated power consumption is 0.1W (200G End) 0.1W (100G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Length Selection and Installation Planning
The additional half metre beyond a one-metre assembly gives MCP7H50-H01AR30 useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
Position Within the Length Range
MCP7H50-H01AR30 occupies the middle of this family between MCP7H50-H001R30 at 1m (3ft) and MCP7H50-H002R26 at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 26mm; the stated power consumption is 0.1W (200G End) 0.1W (100G Per End); the jacket material is PVC (OFNR).
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 26mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP56 to 2 QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
NVIDIA/Mellanox Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original NVIDIA/Mellanox cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7H50-H01AR30.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.