Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FT 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top Active Copper Twinax Cable, 2m (7ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FT 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top Active Copper Twinax Cable, 2m (7ft)

The assembly listed here is the 2m (7ft) member of the OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FT product family for Generic equipment. It provides 800G ACC connectivity through OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top). Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FT

Product Highlights

  • HT-manufactured ACC assembly in 2m (7ft)
  • 800G connectivity at 850Gbps (8x 106.25Gbps)
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 2m (7ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FT
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: 1.3W Per End
  • Minimum bend radius: 48.5mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate850Gbps (8x 106.25Gbps)
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length2m (7ft)
Wire AWG30AWG
Minimum Bend Radius48.5mm
Max. Power Consumption1.3W Per End
Jacket MaterialPET
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation Format8x100G-PAM4
Application800G Ethernet
ProtocolsCMIS 5.0, IEEE 802.3ck, OSFP Rev5.0

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 48.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-2M7FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-1M3FT at 1m (3ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-ACC-3M10FT at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 48.5mm; the stated power consumption is 1.3W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 1.3W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Generic Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles