Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Electrical Cable, 1m (3ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Electrical Cable, 1m (3ft)

This OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT compatible cable gives project teams a defined 800G connection in 1m (3ft), with OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) and Generic host compatibility. Rather than treating all lengths as interchangeable, the page keeps this order code separate and links the other verified lengths for accurate schedules, labels and delivery checks.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT

Product Highlights

  • HT-manufactured AEC assembly in 1m (3ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 1m (3ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT
  • Cable construction: Active DAC (AEC)
  • Conductor specification: 32AWG
  • Maximum power consumption: ≤12W
  • Minimum bend radius: 36.5mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max Data Rate800Gbps
MediaCopper
Cable TypeActive DAC (AEC)
Minimum Bend Radius36.5mm
Power Consumption≤12W
Cable Length1m (3ft)
Wire AWG32AWG
Commercial Temperature Range0 to 70°C (32 to 158°F)
Jacket MaterialPET
ProtocolsOSFP MSA, IEEE 802.3ck, CMIS 5.0
Modulation Format8x100G-PAM4

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 32AWG conductors, PET jacket, minimum bend radius 36.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

At 1m (3ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 36.5mm; the stated power consumption is ≤12W; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is ≤12W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Generic Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-1M3FT.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles