Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT 400G OSFP 4 x 100G PAM4 RHS/Flat Top Passive Copper Twinax Cable, 0.5m (2ft)

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT 400G OSFP 4 x 100G PAM4 RHS/Flat Top Passive Copper Twinax Cable, 0.5m (2ft)

The assembly listed here is the 0.5m (2ft) member of the OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT product family for Generic equipment. It provides 400G DAC connectivity through OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top). Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.

OEM Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FTHT Part Number: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT

Product Highlights

  • HT-manufactured DAC assembly in 0.5m (2ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)
  • Fixed length and part number: 0.5m (2ft), OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 34.5mm

Specifications

HT Part NumberOSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)
Max Data Rate400Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length0.5m (2ft)
Wire AWG30AWG
Minimum Bend Radius34.5mm
Max. Power Consumption0.1W
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, CMIS Rev4.0, IEEE 802.3cd
Modulation Format4x 100G-PAM4

Signal and Lane Configuration

The listed modulation format is 4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 34.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, CMIS Rev4.0, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 34.5mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Generic Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to OSFP (RHS/Flat Top) to OSFP (RHS/Flat Top)-400G-DAC-0.5M2FT.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Neutral packaging and customer-specific packing documentation are available on request.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles