Juniper Networks QDD-2X200G-AOC-15M Compatible 400G QSFP-DD 8 x 50G PAM4 to 2 x 200G QSFP56 4 x 50G PAM4 Ethernet Active Optical Breakout Cable, 15m (49ft)

For project documentation, Juniper Networks QDD-2X200G-AOC-15M and this cable’s physical length should be recorded together. The product described here is a 15m (49ft) AOC assembly for 400G links, using QSFP-DD to 2x QSFP56. Its OEM cross-reference, HT part number, specification table and packing options support traceable ordering and installation records.
OEM Part Number: QDD-2X200G-AOC-15MHT Part Number: QDD-2X200G-AOC-15M
Product Highlights
- Compatible alternative to Juniper Networks QDD-2X200G-AOC-15M
- 400G connectivity at 400Gbps
- Interface configuration: QSFP-DD to 2x QSFP56
- Fixed length and part number: 15m (49ft), QDD-2X200G-AOC-15M
- Cable construction: Breakout AOC
- Maximum power consumption: 12W (QSFP-DD End)5.5W (QSFP56 Per End)
- Minimum bend radius: 30mm
- Operating temperature: 0 to 70°C (32 to 158°F)
Specifications
| HT Part Number | QDD-2X200G-AOC-15M |
|---|---|
| Juniper Networks Compatible | QDD-2X200G-AOC-15M |
| Manufacturer | HT |
| Form Factor | QSFP-DD to 2x QSFP56 |
| Max. Data Rate | 400Gbps |
| Cable Length | 15m (49ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 12W (QSFP-DD End)5.5W (QSFP56 Per End) |
| Modulation Format | QSFP-DD-8x 50G-PAM4QSFP56-4x 50G-PAM4 |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, IEEE 802.3bs, QSFP-DD MSA, SFF-8024, SFF-8679, SFF-8665, CMIS 4.0, OIF-CEI-04.0 |
Juniper Deployment Reference
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
Length Selection and Installation Planning
Longer assemblies require disciplined cable dressing. For QDD-2X200G-AOC-15M at 15m (49ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the integrated optical cable and both optical engines protected throughout the path. Within this family, QDD-2X200G-AOC-10M is shorter at 10m (33ft), while QDD-2X200G-AOC-20M is the next longer choice at 20m (66ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Position Within the Length Range
QDD-2X200G-AOC-15M occupies the middle of this family between QDD-2X200G-AOC-10M at 10m (33ft) and QDD-2X200G-AOC-20M at 20m (66ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 12W (QSFP-DD End)5.5W (QSFP56 Per End); the jacket material is OFNP.
Signal and Lane Configuration
The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 12W (QSFP-DD End)5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, IEEE 802.3bs, QSFP-DD MSA, SFF-8024, SFF-8679, SFF-8665, CMIS 4.0, OIF-CEI-04.0. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP-DD to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Juniper Networks Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Frequently Asked Questions
Is this an original Juniper Networks cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-2X200G-AOC-15M.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to QDD-2X200G-AOC-15M.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.