QSFP 112 to QSFP 112-400G-DAC-1M3FT 400G QSFP112 4 x 100G PAM4 Passive Copper Twinax Cable, 1m (3ft)

The assembly listed here is the 1m (3ft) member of the QSFP 112 to QSFP 112-400G-DAC-1M3FT product family for Generic equipment. It provides 400G DAC connectivity through QSFP 112 to QSFP 112. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: QSFP 112 to QSFP 112-400G-DAC-1M3FTHT Part Number: QSFP 112 to QSFP 112-400G-DAC-1M3FT
Product Highlights
- HT-manufactured DAC assembly in 1m (3ft)
- 400G connectivity at 400Gbps
- Interface configuration: QSFP 112 to QSFP 112
- Fixed length and part number: 1m (3ft), QSFP 112 to QSFP 112-400G-DAC-1M3FT
- Cable construction: Passive Twinax
- Conductor specification: 26AWG
- Maximum power consumption: 0.1W Per End
- Minimum bend radius: 46mm
Specifications
| HT Part Number | QSFP 112 to QSFP 112-400G-DAC-1M3FT |
|---|---|
| Manufacturer | HT |
| Connector Type | QSFP 112 to QSFP 112 |
| Max. Data Rate | 400Gbps |
| Minimum Bend Radius | 46mm |
| Wire AWG | 26AWG |
| Cable Length | 1m (3.28ft) |
| Jacket Material | PET |
| Cable Type | Passive Twinax |
| Compatible | Generic |
| Max. Power Consumption | 0.1W Per End |
| Power Supply | 3.3V |
| Temperature | 0 to 70°C (32 to 158°F) |
| Application | 400G Ethernet |
| Modulation Technology | 4x106.25Gb/s PAM4 |
| Protocol | CMIS 5.0SFF-8024 |
Power and Thermal Planning
The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Network and Protocol Considerations
The intended application is 400G Ethernet.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
At 1m (3ft), QSFP 112 to QSFP 112-400G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
Position Within the Length Range
QSFP 112 to QSFP 112-400G-DAC-1M3FT occupies the middle of this family between QSFP 112 to QSFP 112-400G-DAC-0.5M2FT at 0.5m (2ft) and QSFP 112 to QSFP 112-400G-DAC-1.5M5FT at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 46mm; the stated power consumption is 0.1W Per End; the jacket material is PET.
Cable Construction and Routing
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 46mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.