QSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FT 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 30m (98ft)

QSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FT 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 30m (98ft)

This QSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FT compatible cable gives project teams a defined 200G connection in 30m (98ft), with QSFP-DD to 2x 100G QSFP28 and Generic host compatibility. Rather than treating all lengths as interchangeable, the page keeps this order code separate and links the other verified lengths for accurate schedules, labels and delivery checks.

OEM Part Number: QSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FTHT Part Number: QSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FT

Product Highlights

  • HT-manufactured AOC assembly in 30m (98ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 2x 100G QSFP28
  • Fixed length and part number: 30m (98ft), QSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FT
  • Cable construction: OM3
  • Maximum power consumption: 4W (QSFP-DD End) 2.5W (QSFP28 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FT
ManufacturerHT
Form FactorQSFP-DD to 2x 100G QSFP28
Max. Data Rate200Gbps
Cable Length30m (98ft)
Cable TypeOM3
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption4W (QSFP-DD End) 2.5W (QSFP28 Per End)
Jacket MaterialOFNP
CDR (Clock and Data Recovery)Not Supported
Modulation FormatNRZ
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636

Signal and Lane Configuration

The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The QSFP-DD to 2x 100G QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

Longer assemblies require disciplined cable dressing. For QSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FT at 30m (98ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the integrated optical cable and both optical engines protected throughout the path. Within this family, QSFP-DD to 2x 100G QSFP28-200G-AOC-25M82FT is shorter at 25m (82ft), while QSFP-DD to 2x 100G QSFP28-200G-AOC-50M164FT is the next longer choice at 50m (164ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QSFP-DD to 2x 100G QSFP28-200G-AOC-30M98FT occupies the middle of this family between QSFP-DD to 2x 100G QSFP28-200G-AOC-25M82FT at 25m (82ft) and QSFP-DD to 2x 100G QSFP28-200G-AOC-50M164FT at 50m (164ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 20m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Generic Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 30m (98ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles