QSFP-DD to 2x QSFP56-400G-ACC-2M7FT 400G QSFP-DD 8 x 50G PAM4 to 2 x 200G QSFP56 4 x 50G PAM4 Active Copper Breakout Cable, 2m (7ft)

The assembly listed here is the 2m (7ft) member of the QSFP-DD to 2x QSFP56-400G-ACC-2M7FT product family for Generic equipment. It provides 400G ACC connectivity through QSFP-DD to 2x QSFP56. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: QSFP-DD to 2x QSFP56-400G-ACC-2M7FTHT Part Number: QSFP-DD to 2x QSFP56-400G-ACC-2M7FT
Product Highlights
- HT-manufactured ACC assembly in 2m (7ft)
- 400G connectivity at 400Gbps
- Interface configuration: QSFP-DD to 2x QSFP56
- Fixed length and part number: 2m (7ft), QSFP-DD to 2x QSFP56-400G-ACC-2M7FT
- Cable construction: Active
- Conductor specification: 30AWG
- Maximum power consumption: 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End)
- Minimum bend radius: 70mm
Specifications
| HT Part Number | QSFP-DD to 2x QSFP56-400G-ACC-2M7FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 2x QSFP56 |
| Max. Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Active |
| Cable Length | 2m (7ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 70mm |
| Max. Power Consumption | 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End) |
| Jacket Material | PVC |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFF-8636, SFF-8679 |
Power and Thermal Planning
The rated power consumption is 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8636, SFF-8679. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP-DD to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Length Selection and Installation Planning
QSFP-DD to 2x QSFP56-400G-ACC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
Position Within the Length Range
QSFP-DD to 2x QSFP56-400G-ACC-2M7FT occupies the middle of this family between QSFP-DD to 2x QSFP56-400G-ACC-1M3FT at 1m (3ft) and QSFP-DD to 2x QSFP56-400G-ACC-3M10FT at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 70mm; the stated power consumption is 1.45W(QSFP-DD End) 0.62W(QSFP56 Per End); the jacket material is PVC.
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 70mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. QSFP-DD to 2x QSFP56-400G-ACC-2M7FT refers here to 2m (7ft). Every other verified length has a separate part number and page in the length list.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to QSFP-DD to 2x QSFP56-400G-ACC-2M7FT.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.