QSFP-DD to 8x SFP28-200G-DAC-2M7FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Passive Copper Breakout Cable, 2m (7ft)

The assembly listed here is the 2m (7ft) member of the QSFP-DD to 8x SFP28-200G-DAC-2M7FT product family for Generic equipment. It provides 200G DAC connectivity through QSFP-DD to 8x SFP28. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: QSFP-DD to 8x SFP28-200G-DAC-2M7FTHT Part Number: QSFP-DD to 8x SFP28-200G-DAC-2M7FT
Product Highlights
- HT-manufactured DAC assembly in 2m (7ft)
- 200G connectivity at 200Gbps
- Interface configuration: QSFP-DD to 8x SFP28
- Fixed length and part number: 2m (7ft), QSFP-DD to 8x SFP28-200G-DAC-2M7FT
- Cable construction: Passive Breakout DAC
- Conductor specification: 28AWG
- Maximum power consumption: 0.1W (QSFP-DD End)0.1W (SFP28 Per End)
- Minimum bend radius: 22.5mm
Specifications
| HT Part Number | QSFP-DD to 8x SFP28-200G-DAC-2M7FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 8x SFP28 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Minimum Bend Radius | 22.5mm |
| Wire AWG | 28AWG |
| Cable Length | 2m (7ft) |
| Jacket Material | PVC (OFNR) |
| Max. Power Consumption | 0.1W (QSFP-DD End)0.1W (SFP28 Per End) |
| Modulation Format | QSFP-DD-8x 25G-NRZSFP28-25G-NRZ |
| DDM/DOM | Not Supported |
| Commercial TemperatureRange | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472 |
Signal and Lane Configuration
The listed modulation format is QSFP-DD-8x 25G-NRZSFP28-25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Position Within the Length Range
QSFP-DD to 8x SFP28-200G-DAC-2M7FT occupies the middle of this family between QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT at 1.5m (5ft) and QSFP-DD to 8x SFP28-200G-DAC-2.5M8FT at 2.5m (8ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 22.5mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End); the jacket material is PVC (OFNR).
Power and Thermal Planning
The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 22.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP-DD to 8x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
QSFP-DD to 8x SFP28-200G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Does this order code cover multiple lengths?
No. QSFP-DD to 8x SFP28-200G-DAC-2M7FT refers here to 2m (7ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Neutral packaging and customer-specific packing documentation are available on request.
