QSFP-DD to QSFP-DD-800G-AEC-5M16FT 800G QSFP-DD 8 x 100G PAM4 Active Electrical Cable, 5m (16ft)

The assembly listed here is the 5m (16ft) member of the QSFP-DD to QSFP-DD-800G-AEC-5M16FT product family for Generic equipment. It provides 800G AEC connectivity through QSFP-DD to QSFP-DD. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: QSFP-DD to QSFP-DD-800G-AEC-5M16FTHT Part Number: QSFP-DD to QSFP-DD-800G-AEC-5M16FT
Product Highlights
- HT-manufactured AEC assembly in 5m (16ft)
- 800G connectivity at 800Gbps
- Interface configuration: QSFP-DD to QSFP-DD
- Fixed length and part number: 5m (16ft), QSFP-DD to QSFP-DD-800G-AEC-5M16FT
- Cable construction: Active DAC (AEC)
- Conductor specification: 32AWG
- Maximum power consumption: 12W Per End
- Minimum bend radius: 36.5
Specifications
| HT Part Number | QSFP-DD to QSFP-DD-800G-AEC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to QSFP-DD |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Cable Length | 5m (16ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 36.5 |
| Wire AWG | 32AWG |
| Max. Power Consumption | 12W Per End |
| Modulation Format | 8x100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G Ethernet |
| Protocols | CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3 |
Signal and Lane Configuration
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 12W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 32AWG conductors, PET jacket, minimum bend radius 36.5. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 800G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
The 5m (16ft) length gives QSFP-DD to QSFP-DD-800G-AEC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the AEC specification and host support must still match the intended link.
Position Within the Length Range
QSFP-DD to QSFP-DD-800G-AEC-5M16FT is the longest of 4 verified length options in this family. Compared with QSFP-DD to QSFP-DD-800G-AEC-3M10FT at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 36.5; the stated power consumption is 12W Per End; the jacket material is PET.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Does this order code cover multiple lengths?
No. QSFP-DD to QSFP-DD-800G-AEC-5M16FT refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to QSFP-DD to QSFP-DD-800G-AEC-5M16FT.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.