QSFP+ to SFP+-40G-ACC-7M23FT 40G QSFP+ to 4 x 10G SFP+ Active Copper Breakout Cable, 7m (23ft)

The assembly listed here is the 7m (23ft) member of the QSFP+ to SFP+-40G-ACC-7M23FT product family for Generic equipment. It provides 40G ACC connectivity through QSFP+ to SFP+. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: QSFP+ to SFP+-40G-ACC-7M23FTHT Part Number: QSFP+ to SFP+-40G-ACC-7M23FT
Product Highlights
- HT-manufactured ACC assembly in 7m (23ft)
- 40G connectivity at 40Gbps
- Interface configuration: QSFP+ to SFP+
- Fixed length and part number: 7m (23ft), QSFP+ to SFP+-40G-ACC-7M23FT
- Cable construction: Active Twinax
- Conductor specification: 26AWG
- Maximum power consumption: ≤1.8W
- Minimum bend radius: 44.5mm
Specifications
| HT Part Number | QSFP+ to SFP+-40G-ACC-7M23FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP+ to SFP+ |
| Max Data Rate | 40Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 7m (23ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 44.5mm |
| Power Consumption | ≤1.8W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8431, SFF-8432, SFF-8472 SFP+ MSA, SFF-8436 QSFP+ MSA |
Power and Thermal Planning
The rated power consumption is ≤1.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Length Selection and Installation Planning
For this 7m (23ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the complete copper assembly and both connector housings as one factory-terminated product and never pull a connector into position by the cable. Within this family, QSFP+ to SFP+-40G-ACC-5M16FT is shorter at 5m (16ft), while QSFP+ to SFP+-40G-ACC-9M29FT is the next longer choice at 9m (29ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Position Within the Length Range
QSFP+ to SFP+-40G-ACC-7M23FT occupies the middle of this family between QSFP+ to SFP+-40G-ACC-5M16FT at 5m (16ft) and QSFP+ to SFP+-40G-ACC-9M29FT at 9m (29ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 44.5mm; the stated power consumption is ≤1.8W; the jacket material is PVC (OFNR).
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 44.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8431, SFF-8432, SFF-8472 SFP+ MSA, SFF-8436 QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP+ to SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Does this order code cover multiple lengths?
No. QSFP+ to SFP+-40G-ACC-7M23FT refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Keep QSFP+ to SFP+-40G-ACC-7M23FT associated with 7m (23ft) throughout the order and receiving record.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.