QSFP+ to SFP+-40G-ACC-9M29FT 40G QSFP+ to 4 x 10G SFP+ Active Copper Breakout Cable, 9m (29ft)

This QSFP+ to SFP+-40G-ACC-9M29FT compatible cable gives project teams a defined 40G connection in 9m (29ft), with QSFP+ to SFP+ and Generic host compatibility. Rather than treating all lengths as interchangeable, the page keeps this order code separate and links the other verified lengths for accurate schedules, labels and delivery checks.
OEM Part Number: QSFP+ to SFP+-40G-ACC-9M29FTHT Part Number: QSFP+ to SFP+-40G-ACC-9M29FT
Product Highlights
- HT-manufactured ACC assembly in 9m (29ft)
- 40G connectivity at 40Gbps
- Interface configuration: QSFP+ to SFP+
- Fixed length and part number: 9m (29ft), QSFP+ to SFP+-40G-ACC-9M29FT
- Cable construction: Active Twinax
- Conductor specification: 26AWG
- Maximum power consumption: ≤1.8W
- Minimum bend radius: 44.5mm
Specifications
| HT Part Number | QSFP+ to SFP+-40G-ACC-9M29FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP+ to SFP+ |
| Max Data Rate | 40Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 9m (29ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 44.5mm |
| Power Consumption | ≤1.8W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8431, SFF-8432, SFF-8472 SFP+ MSA, SFF-8436 QSFP+ MSA |
Power and Thermal Planning
The rated power consumption is ≤1.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Position Within the Length Range
QSFP+ to SFP+-40G-ACC-9M29FT is the longest of 5 verified length options in this family. Compared with QSFP+ to SFP+-40G-ACC-7M23FT at 7m (23ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 44.5mm; the stated power consumption is ≤1.8W; the jacket material is PVC (OFNR).
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 44.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8431, SFF-8432, SFF-8472 SFP+ MSA, SFF-8436 QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP+ to SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Length Selection and Installation Planning
With 9m (29ft) available, the installer has more routing freedom but also more cable to control. Determine where any remaining service loop will be stored, preserve the stated bend radius and keep the loop away from sharp edges and hot exhaust. The complete copper assembly and both connector housings should remain accessible for inspection and removal. The next shorter verified assembly is QSFP+ to SFP+-40G-ACC-7M23FT at 7m (23ft), which is the better comparison when the managed route leaves substantial unused cable.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Keep QSFP+ to SFP+-40G-ACC-9M29FT associated with 9m (29ft) throughout the order and receiving record.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Neutral packaging and customer-specific packing documentation are available on request.