QSFP112 to QSFP112-400G-AEC-3M10FT 400G QSFP112 4 x 100G PAM4 Active Electrical Cable, 3m (10ft)

For project documentation, Generic QSFP112 to QSFP112-400G-AEC-3M10FT and this cable’s physical length should be recorded together. The product described here is a 3m (10ft) AEC assembly for 400G links, using QSFP112 to QSFP112. Its OEM cross-reference, HT part number, specification table and packing options support traceable ordering and installation records.
OEM Part Number: QSFP112 to QSFP112-400G-AEC-3M10FTHT Part Number: QSFP112 to QSFP112-400G-AEC-3M10FT
Product Highlights
- HT-manufactured AEC assembly in 3m (10ft)
- 400G connectivity at 400Gbps
- Interface configuration: QSFP112 to QSFP112
- Fixed length and part number: 3m (10ft), QSFP112 to QSFP112-400G-AEC-3M10FT
- Cable construction: Active DAC (AEC)
- Conductor specification: 32AWG
- Maximum power consumption: <8W Per End
- Minimum bend radius: 26.5mm
Specifications
| HT Part Number | QSFP112 to QSFP112-400G-AEC-3M10FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP112 to QSFP112 |
| Max. Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Minimum Bend Radius | 26.5mm |
| Wire AWG | 32AWG |
| Cable Length | 3m (10ft) |
| Jacket Material | PET |
| Power Consumption | <8W Per End |
| Modulation Format | 4x 100G-PAM4 |
| DDM/DOM | Supported |
| Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP112 MSA, IEEE 802.3ck 400GBase-CR4, CMIS 5.0 |
Signal and Lane Configuration
The listed modulation format is 4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Position Within the Length Range
QSFP112 to QSFP112-400G-AEC-3M10FT is the longest of 3 verified length options in this family. Compared with QSFP112 to QSFP112-400G-AEC-2M7FT at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 26.5mm; the stated power consumption is <8W Per End; the jacket material is PET.
Power and Thermal Planning
The rated power consumption is <8W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 32AWG conductors, PET jacket, minimum bend radius 26.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP112 MSA, IEEE 802.3ck 400GBase-CR4, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.