QSFP28 to 4 duplex LC-100G-AOC-1M3FT 100G QSFP28 4 x 25G NRZ to 4 Duplex LC 25G NRZ Active Optical Breakout Cable, 1m (3ft)

For project documentation, Generic QSFP28 to 4 duplex LC-100G-AOC-1M3FT and this cable’s physical length should be recorded together. The product described here is a 1m (3ft) AOC assembly for 100G links, using QSFP28 to 4 duplex LC. Its OEM cross-reference, HT part number, specification table and packing options support traceable ordering and installation records.
OEM Part Number: QSFP28 to 4 duplex LC-100G-AOC-1M3FTHT Part Number: QSFP28 to 4 duplex LC-100G-AOC-1M3FT
Product Highlights
- HT-manufactured AOC assembly in 1m (3ft)
- 100G connectivity at 100Gbps
- Interface configuration: QSFP28 to 4 duplex LC
- Fixed length and part number: 1m (3ft), QSFP28 to 4 duplex LC-100G-AOC-1M3FT
- Cable construction: Breakout AOC
- Maximum power consumption: 2.2W
- Minimum bend radius: 20mm
- Operating temperature: 0 to 70°C (32 to 158°F)
Specifications
| HT Part Number | QSFP28 to 4 duplex LC-100G-AOC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP28 to 4 duplex LC |
| Max. Data Rate | 100Gbps |
| Cable Length | 1m (3ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 20mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Max. Power Consumption | 2.2W |
| Modulation Format | QSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8436, SFF-8431 |
Signal and Lane Configuration
The listed modulation format is QSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 20mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP28 to 4 duplex LC configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
At 1m (3ft), QSFP28 to 4 duplex LC-100G-AOC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
Position Within the Length Range
QSFP28 to 4 duplex LC-100G-AOC-1M3FT is the shortest of 11 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP28 to 4 duplex LC-100G-AOC-3M10FT at 3m (10ft), adding 2m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the minimum bend radius is 20mm; the stated power consumption is 2.2W; the jacket material is OFNP.
Power and Thermal Planning
The rated power consumption is 2.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Does this order code cover multiple lengths?
No. QSFP28 to 4 duplex LC-100G-AOC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Keep QSFP28 to 4 duplex LC-100G-AOC-1M3FT associated with 1m (3ft) throughout the order and receiving record.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.