QSFP28 to QSFP28-100G-DAC-5M16FT 100G QSFP28 4 x 25G NRZ Passive Copper Twinax Cable, 5m (16ft)

QSFP28 to QSFP28-100G-DAC-5M16FT 100G QSFP28 4 x 25G NRZ Passive Copper Twinax Cable, 5m (16ft)

This QSFP28 to QSFP28-100G-DAC-5M16FT compatible cable gives project teams a defined 100G connection in 5m (16ft), with QSFP28 to QSFP28 and Generic host compatibility. Rather than treating all lengths as interchangeable, the page keeps this order code separate and links the other verified lengths for accurate schedules, labels and delivery checks.

OEM Part Number: QSFP28 to QSFP28-100G-DAC-5M16FTHT Part Number: QSFP28 to QSFP28-100G-DAC-5M16FT

Product Highlights

  • HT-manufactured DAC assembly in 5m (16ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to QSFP28
  • Fixed length and part number: 5m (16ft), QSFP28 to QSFP28-100G-DAC-5M16FT
  • Cable construction: Passive Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 45mm

Specifications

HT Part NumberQSFP28 to QSFP28-100G-DAC-5M16FT
ManufacturerHT
Form FactorQSFP28 to QSFP28
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length5m (16.4ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius45mm
Wire AWG26AWG
Max. Power Consumption≤0.5W
Modulation Format4x 25G-NRZ to 4x 25G-NRZ
Power Supply3.3V
MTBF≈50 Million Hours
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet
ProtocolsQSFP28 MSA, SFF-8662, IEEE 802.3

Signal and Lane Configuration

The listed modulation format is 4x 25G-NRZ to 4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

QSFP28 to QSFP28-100G-DAC-5M16FT is the longest of 6 verified length options in this family. Compared with QSFP28 to QSFP28-100G-DAC-3M10FT at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 45mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 45mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet. Listed interface and protocol references include QSFP28 MSA, SFF-8662, IEEE 802.3. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 5m (16ft) length gives QSFP28 to QSFP28-100G-DAC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.

Generic Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. QSFP28 to QSFP28-100G-DAC-5M16FT refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Standard protective packing is used by default, with project documentation arranged when requested.