QSFP56 to QSFP56-200G-ACC-5M16FT 200G QSFP56 4 x 50G PAM4 Active Copper Twinax Cable, 5m (16ft)

The assembly listed here is the 5m (16ft) member of the QSFP56 to QSFP56-200G-ACC-5M16FT product family for Generic equipment. It provides 200G ACC connectivity through QSFP56 to QSFP56. Project teams can use the detailed table, related references and documentation-oriented packing information to keep each delivered cable aligned with its planned endpoints.
OEM Part Number: QSFP56 to QSFP56-200G-ACC-5M16FTHT Part Number: QSFP56 to QSFP56-200G-ACC-5M16FT
Product Highlights
- HT-manufactured ACC assembly in 5m (16ft)
- 200G connectivity at 200Gbps
- Interface configuration: QSFP56 to QSFP56
- Fixed length and part number: 5m (16ft), QSFP56 to QSFP56-200G-ACC-5M16FT
- Cable construction: Active Twinax
- Conductor specification: 28AWG
- Maximum power consumption: 1.5W Per End
- Minimum bend radius: 40mm
Specifications
| HT Part Number | QSFP56 to QSFP56-200G-ACC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP56 to QSFP56 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 5m (16ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 40mm |
| Max. Power Consumption | 1.5W Per End |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636 |
Power and Thermal Planning
The rated power consumption is 1.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Length Selection and Installation Planning
The 5m (16ft) length gives QSFP56 to QSFP56-200G-ACC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
Position Within the Length Range
QSFP56 to QSFP56-200G-ACC-5M16FT occupies the middle of this family between QSFP56 to QSFP56-200G-ACC-4M13FT at 4m (13ft) and QSFP56 to QSFP56-200G-ACC-7M23FT at 7m (23ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40mm; the stated power consumption is 1.5W Per End; the jacket material is PVC (OFNR).
Cable Construction and Routing
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 40mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Volume orders can include customer references on the labels and carton list.
