SC APC Simplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

SC APC Simplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

For Pakistani procurement and engineering teams, the specification provides a practical basis for checking compatibility before production is requested. This simplex armored patch cable carries a single OS2 9/125µm fiber between two SC APC connectors, protected by a helical stainless steel tube under the blue 3.0mm riser-rated (OFCR) jacket. The angled APC polish holds return loss at 60dB or better, which is exactly what PON, CATV and other reflection-sensitive single-fiber systems demand, whereas the steel armor guards the exposed last meters of the connection.

Product Highlights

  • Riser (OFCR) flame rating for vertical building pathways
  • Stock lengths 1m to 30m; custom lengths and jackets on request
  • SC APC to SC APC simplex, OS2 9/125µm single mode
  • Angled 8° polish for ≥60dB return loss
  • Helical stainless steel armor against crush, impact and rodents
  • G.657.A1 bend-insensitive fiber, 10/5D bend radius

Specifications

Connector TypeSC to SC
Polish TypeAPC to APC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountSimplex
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingRiser (OFCR)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥60dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

APC polish for reflection-sensitive systems

APC ferrules are ground at an 8-degree angle so that reflected light leaves the guided route instead of returning toward the source. In PON access networks, RF video overlay and DWDM links, that reflected power would otherwise destabilize lasers and corrupt the signal. The green SC housings mark the angled polish instantly, and the measured 60dB return loss is the figure those systems are engineered around.

Simplex cords for single-fiber transmission

A simplex cord carries one fiber and one direction of traffic, which matches BiDi transceivers, WDM systems, optical monitoring taps and test access points. Where a duplex cord would leave one fiber dark and coiled in the tray, the simplex build keeps the patching field cleaner and makes tracing a single strand straightforward. For Pakistani projects, include this point in the technical enquiry and final installation checklist.

Armored protection for access-network tails

The last meters of a FTTx or access connection are normally the most exposed: wall outlets, cabinet doors, drop terminals and basement risers. A helical steel tube around the buffered fiber means these tails survive being stepped on, kinked behind furniture-grade enclosures or chewed in utility spaces, without the installer having to sleeve the run in conduit.

FTTx and PON applications

In PON plant this cord usually appears between the OLT or splitter cabinet and the first distribution point, and as the service tail at customer premises. Because the APC polish is what PON was standardized around, the cord drops into GPON, XGS-PON and NG-PON2 links without return-loss concerns. Where the plant uses LSZH jackets indoors, the LSZH version of the identical build keeps the jacket policy consistent end to end.

Standard and custom length options

Catalogue lengths are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Special lengths beyond this range are manufactured to order. In access networks the tail is frequently cut into a present plan, and therefore give the measured path length and the cord arrives without surplus slack to store behind the ODF. Specifying the precise path length avoids the two the slack storage problem of an overlong cord and the strain risk of one that is too short.

Test standards and quality control

Every unit is terminated with precision zirconia ferrule SC APC connectors and measured for insertion loss and return loss before packing; the two the 0.3dB insertion ceiling and the 60dB return floor are verified per cord. Apex offset and fiber height are checked to keep the angled physical contact consistent over repeat matings.

Ordering Details and Factory Support

Reference against the SC APC simplex armored series with the path length and jacket rating stated. For other connector or polish combinations, including hybrid LC-to-SC builds, use the custom-built simplex armored program and the factory will make certain of the specification before factory assembly. For Pakistan, a clear port or maintenance schedule helps us confirm the correct factory-built configuration before supply.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.