SC APC to SC APC Fiber Drop Cable, OS2, Custom Length

For Pakistani procurement and engineering teams, the specification provides a practical basis for checking compatibility before production is requested. This fiber drop cable closes the last span of the FTTH access network, running from the distribution point or splice closure to the subscriber premises. Because the two interfaces are factory terminated with SC APC connectors, the connection plugs directly into the optical network terminal and the distribution hardware without field splicing. The installed cable is the proven flat drop build: one OS2 9/125µm single-mode fiber of G.657.A2 bend-insensitive glass in a 2.0x5.0mm LSZH jacket, manufactured to the precise length the path requires.
Product Highlights
- Plug-and-play installation, no field splicing required
- Manufactured to the ordered route length
- SC APC to SC APC, factory terminated and tested
- G.657.A2 bend-insensitive fiber, 7.5mm minimum bend radius
- Flat 2.0x5.0mm LSZH drop cable construction
- Insertion loss ≤0.3dB, return loss ≥60dB
Specifications
| Connector A | SC APC |
|---|---|
| Connector B | SC APC |
| Fiber Mode | OS2 9/125µm |
| Wavelength | 1310/1550nm |
| Fiber Count | 1 Fiber |
| Fiber Grade | G.657.A2 |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 60/40mm (Dynamic/Static) |
| Trunk Outside Diameter (OD) | 2.0x5.0mm |
| Breakout Outside Diameter (OD) | 2.0x3.0mm |
| Breakout Length | 300±50mm |
| Cable Jacket | Low Smoke Zero Halogen (LSZH) |
| Tensile Load | 400N (Short Term) |
| Crush Resistance | 500N/100mm (Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥60dB |
| Attenuation at 1310nm | ≤0.4dB/km |
| Attenuation at 1550nm | ≤0.3dB/km |
| Operating Temperature | -20 to 70°C (-4 to 158°F) |
| Storage Temperature | -10 to 50°C (14 to 122°F) |
The last-mile link in FTTH networks
Between the distribution point and the subscriber, the drop cable is the most frequently handled and most frequently replaced part of the access network. It crosses walls, window frames, conduit entries and the final indoor path to the optical network terminal. A factory-prepared drop cable turns that span into a plug-and-play connection: the installer routes the installed cable, seats the two connectors, and the subscriber is live. No splicer, no curing time and no field polishing enter the layout, which is exactly what high-volume FTTH rollouts need.
Why APC polish matters in PON access
Access networks built on GPON and XGS-PON carry downstream video overlay and high-power optical budget on shared splitters, where reflections travel back toward each subscriber on the PON. The angled physical contact end-face of the SC APC connector keeps return loss at 60dB or better, steering reflections away from the upstream route. Mixing UPC patch cords into an APC-planned PON creates reflectance events that are hard to trace later, and therefore the drop segment ought to observe the APC discipline of the rest of the plant.
G.657.A2 glass for real subscriber premises
The indoor part of a drop path turns around door frames, baseboards and furniture edges, and it is frequently stapled or clipped by technicians working quickly. Because G.657.A2 fiber tolerates a 7.5mm bend radius at the glass level, the tight corners of a real apartment make sure not to add measurable loss. The flat 2.0x5.0mm build with its parallel strength members keeps the installed cable lying flat against surfaces and protects the core from the crushing loads of staples and clips.
Custom length as the standard practice
Drop routes vary from a few meters in a townhouse to over a hundred meters on a rural lot, and a wrong guess in either direction costs time: too short means a replacement visit, too long means a coil of slack at the terminal. Ordering the drop cable to the measured path length removes the two failure modes. The 300mm breakout at the optical interface ends is part of the standard build, giving sufficient free fiber to dress into the closure or the terminal without strain.
Route length and custom builds
Since last-mile routes differ from a few meters to well over a hundred, each drop cable in this series is manufactured to the length stated with the order rather than picked from fixed stock sizes,. The installed cable is manufactured to the length stated with the order; measure the path including the vertical drops and the entry route, and allow working slack at the two interfaces for the closure and the terminal. Specifying the measured path length avoids the two the slack storage problem of an overlong cable and the strain risk of one that is too short.
Test standards and quality control
Each drop cable is terminated with precision zirconia ferrule SC APC connectors and optically tested before packing: insertion loss is verified against the 0.3dB ceiling and return loss against the 60dB minimum on every unit. Because end-face geometry is inspected for consistent physical contact, the delivered cable can also be plugged in and put into service without on-site rework.
Ordering Details and Factory Support
Refer to the SC APC to SC APC drop cable series when specifying a quotation and state the path length and number of units per length. For sealed outdoor termination at the distribution end, the hardened-connector versions of this series mate directly with IP68 terminal ports; send the site specification with the request and the factory will make certain of the build before factory assembly. For Pakistan, a clear port or maintenance schedule helps us confirm the correct factory-built configuration before supply.