Pakistan Fiber Optics

Fiber Optic Products Manufacturing since 1998

Cisco SFP-H25G-CU4M Compatible 25G SFP28 Passive Copper Twinax Cable, 4m (13ft)

Cisco SFP-H25G-CU4M Compatible 25G SFP28 Passive Copper Twinax Cable, 4m (13ft)

For project documentation, Cisco SFP-H25G-CU4M and this cable’s physical length should be recorded together. The product described here is a 4m (13ft) DAC assembly for 25G links, using SFP28 to SFP28. Its OEM cross-reference, HT part number, specification table and packing options support traceable ordering and installation records.

OEM Part Number: SFP-H25G-CU4MHT Part Number: SFP-H25G-CU4M

Product Highlights

  • Compatible alternative to Cisco SFP-H25G-CU4M
  • 25G connectivity at 25Gbps
  • Interface configuration: SFP28 to SFP28
  • Fixed length and part number: 4m (13ft), SFP-H25G-CU4M
  • Conductor specification: 26AWG
  • Minimum bend radius: 28mm

Specifications

HT Part NumberSFP-H25G-CU4M
Cisco CompatibleSFP-H25G-CU4M
ManufacturerHT
Connector TypeSFP28 to SFP28
Max Data Rate25Gbps
Minimum Bend Radius28mm
Wire AWG26AWG
Cable Length4m (13.12ft)
Jacket MaterialPVC (OFNR)
Temperature0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000
Application25G Ethernet, Data Center, 5G Wireless

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 4m (13ft) length gives SFP-H25G-CU4M more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.

Position Within the Length Range

SFP-H25G-CU4M occupies the middle of this family between SFP-H25G-CU3M at 3m (10ft) and SFP-H25G-CU5M at 5m (16ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Project Documentation and Cable Identification

Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28mm; the jacket material is PVC (OFNR).

Network and Protocol Considerations

The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.

Cisco Compatibility and Factory Testing

Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco SFP-H25G-CU4M.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Ordering Information

Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to SFP-H25G-CU4M.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Neutral packaging and customer-specific packing documentation are available on request.


You are here



Pakistan Fiber Optics

Service Center:Islamabad,Pakistan
China Factory: Bao'an,Shenzhen
web: https://www.fiberoptic.com.pk
Professional fibre optic supplier.

Our Social Profiles