SFP28 to SFP28-25G-ACC-4M13FT 25G SFP28 Active Copper Twinax Cable, 4m (13ft)

For project documentation, Generic SFP28 to SFP28-25G-ACC-4M13FT and this cable’s physical length should be recorded together. The product described here is a 4m (13ft) ACC assembly for 25G links, using SFP28 to SFP28. Its OEM cross-reference, HT part number, specification table and packing options support traceable ordering and installation records.
OEM Part Number: SFP28 to SFP28-25G-ACC-4M13FTHT Part Number: SFP28 to SFP28-25G-ACC-4M13FT
Product Highlights
- HT-manufactured ACC assembly in 4m (13ft)
- 25G connectivity at 25Gbps
- Interface configuration: SFP28 to SFP28
- Fixed length and part number: 4m (13ft), SFP28 to SFP28-25G-ACC-4M13FT
- Cable construction: Active Twinax
- Conductor specification: 30AWG
- Maximum power consumption: ≤0.5W
- Minimum bend radius: 22.5mm
Specifications
| HT Part Number | SFP28 to SFP28-25G-ACC-4M13FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 4m (13ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 22.5mm |
| Power Consumption | ≤0.5W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3, SFP28 MSA, SFF-8402 |
Power and Thermal Planning
The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Position Within the Length Range
SFP28 to SFP28-25G-ACC-4M13FT occupies the middle of this family between SFP28 to SFP28-25G-ACC-3M10FT at 3m (10ft) and SFP28 to SFP28-25G-ACC-5M16FT at 5m (16ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Project Documentation and Cable Identification
Large deployments are easier to audit when the order code, physical length and endpoint record agree. Keep the OEM reference in the compatibility document and use the HT part number on the packing list. Where several lengths arrive together, labels and carton groups can be arranged by rack or port plan so installers do not have to identify cables by appearance alone. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 22.5mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 22.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
The 4m (13ft) length gives SFP28 to SFP28-25G-ACC-4M13FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
Generic Compatibility and Factory Testing
Factory verification links the compatibility identity to the exact physical assembly described on this page. Identification, connector condition and live link behavior are checked before packing. Customers can submit equipment and firmware details with the project documentation for a more specific pre-order compatibility review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Ordering Information
Use the listed HT part number for ordering and retain the OEM reference as the host-compatibility cross-reference. Send quantities by length, along with any rack-based packing or label instructions. If the project has mixed equipment, include the host model for each group rather than relying only on the aggregate cable rate. Quantity and any labeling instructions should be attached specifically to SFP28 to SFP28-25G-ACC-4M13FT.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Quality Assurance and Packaging
Inspection and link testing are completed before the cable enters its protective packaging. Project orders can be packed and labelled by length, rack or customer reference, with packing documentation that makes received quantities straightforward to reconcile against the installation schedule. Neutral packaging and customer-specific packing documentation are available on request.